Floor - Structural concrete slab and exposed concrete surface.

Demising Walls - Demising walls separating the unit from the remaining units shall be constructed of either taped and sanded drywall on metal studs (complete with acoustic insulation) and/or exposed re-enforced concrete columns/walls and/or block wall. The outside perimeter wall adjacent to the common corridor(s) will be constructed of taped and sanded drywall on metal studs complete with thermal insulation.

Ceiling - Exposed concrete ceiling; ceiling heights on level 1 will be approximately between 3.10 M to 3.64M .Ceiling heights on level 2 will be 2.90M.

Office Entry - Veneer wood door with brushed stainless steel lever hardware. Electrical - 100 amps, 120/208 volts, 3 phase, 4 wire service, complete with 100A, 3 phase, 42 circuit panel board. The panel board will be equipped with one single pole breaker connected to an in-suite fan coil unit and 41 circuit breaker spaces. The panel board will be installed in accordance with the vendor's architectural and electrical plans.

Telephone/Cable - Two (2) empty conduits for telephone and/or cable television will be provided to a point within the unit from the condominium's telephone/cable room, in accordance with the service provider's requirements and equipment.

HVAC - (Heating, Ventilation and Air Condition) system is provided by water source heat pump units mounted the ceiling of associated retail unit/office. Each heat pump unit shall be connected to heat pump heating/cooling supply and return pipes which are capped in the ceiling of each unit/office. Outdoor or fresh air for each retail unit/office is capped in the ceiling.

Plumbing - 25mm (1") domestic hot and cold water are provided for each unit/office and capped in the ceiling. 100mm (4") sanitary drain line capped in the ceiling of floor below for each retail unit/office and associated vent line is capped in the ceiling of the retail unit/office. (There is no gas service to the unit.)

Life Safety Systems - Each unit will be equipped with a fire alarm speaker.

Meters - The unit will be sub-metered for electrical, heating, cooling, and cold water consumption. Exterior wall - the exterior wall comprises a glazed curtain wall with energy efficient windows.

Please note: The Vendor shall have the right to make reasonable changes in the opinion of the Vendor in the plans and specifications if required and to substitute other material for that provided for herein with material that is of equal or better quality than that provided for herein. The determination of whether or not a substitute material is of equal or better quality shall be made by the Vendor's architect whose determination shall be final and binding. Colour, texture, appearance, etc. of features and finishes installed in the Unit may vary from Vendor's samples as a result of normal manufacturing and installation processes.